Test Code VITD Vitamin D Level
Additional Codes
LAB2301
Performing Laboratory
Central Peninsula Hospital
Collection Method
Venipuncture
Container
Serum (Gold SST or red top tube)
Specimen Type
Preferred
- Serum- Gold Top SST or Red Top
Acceptable
- Plasma- Light Green Top
Minimum Volume
0.5ml
Specimen Stability
Ambient | 8 hours |
Refrigerated (4°C to 8°C) | 4 days |
Frozen(-40°C to 0°C) | 24 weeks |
Reference or Target Ranges
Age | Male | Female |
all ages | >30 | >30 |
Deficient: <20 ng/mL
Insufficient: 20-30 ng/mL
Optimal: > 30 ng/mL
Reportable Units
ng/mL
Critical Value
Not defined for this assay
Reasons for Rejection
Hemolysis Threshold | 600 mg/dL |
Icterus Threshold | 66 mg/dL |
Lipemia Threshold | 300 mL |
Other | QNS, contaminated, improperly labeled, improper specimen type |
Performance Information
Days and Time Performed | 24/7 |
Expected Turn Around Time |
Stat: 1 hour Routine: 4 hours |
Stat Availability | Yes |
Performing Bench | CPH Chemistry |
Methodology/Method Description | Roche Cobas |
CPT Codes
82306
Last review/edit date