Test Code TRIG Triglycerides, Plasma or Serum
Additional Codes
LAB134
Collection Method
Venous collection
Container
Lt Green / Plasma Separator / Lithium Heparin
Acceptable Specimens
Serum:
- Gold Top SST
- Red Top
Plasma:
- Light Geen Top (Lithium heparin)
Minimum Volume
Triglycerides, Plasma or Serum
Reference or Target Ranges
Age | Male | Female |
< 2 years | Reference Range Not Established | Reference Range Not Established |
2 - 9 years |
<75 comment 1 |
<75 comment 1 |
10 - 17 years |
<90 comment 2 |
<90 comment 2 |
> 18 years | <150 | <150 |
comment 1:
Acceptable < 75 mg/dl
Borderline high 75 - 99 mg/dl
High ≥ 100 mg/dl
comment 2:
Acceptable < 90 mg/dl
Borderline high 90 - 129 mg/dl
High ≥ 130 mg/dl
Reportable Units
mg/dL
Critical Value
Not defined for this assay
Reasons for Rejection
Hemolysis Threshold | 500 mg/dL |
Icterus Threshold | 40 mg/dL |
Lipemia Threshold | N/A |
Other | QNS, contaminated, improperly Labeled, improper specimen type |
Specimen Stability
Ambient | 8 hours |
Refrigerated (4°C to 8°C) | Plasma: 15 days Serum: 10 days |
Frozen(-40°C to 0°C) | 3 months |
Performance Information
Days and Time Performed | 24/7 |
Expected Turn Around Time |
Stat: 1 hour Routine: 4 hours |
Stat Availability | Yes |
Performing Bench | CPH Chemistry |
Methodology/Method Description | Roche Cobas |
CPT Codes
84478
Last review/edit date
2025