Sign in →

Test Code TLYME Lyme IgM and IgG, Whole Cell Sonicate, ELISA, Serum


Ordering Guidance


This test should only be ordered on specimens that have tested positive or equivocal by a first tier Lyme disease antibody test.



Specimen Required


Supplies: Sarstedt Aliquot Tube 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.6 mL Serum

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Type

Serum

Specimen Minimum Volume

Serum: 0.5 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Refrigerated (preferred) 10 days
  Frozen  30 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject
Heat-inactivated Reject

Reference Values

Negative

 

Reference values apply to all ages.

Day(s) Performed

Tuesday, Friday

Report Available

Same day/1 to 5 days

Specimen Retention Time

14 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

86617 x 2