Test Code THCSM Thyroid Function Cascade, Monitor (without Thyroid Peroxidase Antibody), Serum
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1.5 mL
Collection Instructions: Within 2 hours of collection, centrifuge and aliquot serum into a plastic vial.
Reflex Tests
| Test ID | Reporting Name | Available Separately | Always Performed |
|---|---|---|---|
| FRT4C | T4 (Thyroxine), Free, S | Yes | No |
| T3C | T3 (Triiodothyronine), Total, S | Yes | No |
Specimen Type
SerumSpecimen Minimum Volume
1 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Refrigerated (preferred) | 7 days |
| Frozen | 30 days | |
| Ambient | 72 hours |
Reject Due To
| Gross hemolysis | Reject |
| Gross lipemia | OK |
| Gross icterus | OK |
Reference Values
0-5 days: 0.7-15.2 mIU/L
6 days-2 months: 0.7-11.0 mIU/L
3-11 months: 0.7-8.4 mIU/L
1-5 years: 0.7-6.0 mIU/L
6-10 years: 0.6-4.8 mIU/L
11-19 years: 0.5-4.3 mIU/L
≥20 years: 0.3-4.2 mIU/L
Day(s) Performed
Monday through Sunday
Report Available
Same day/1 to 2 daysSpecimen Retention Time
7 daysPerforming Laboratory
Mayo Clinic Laboratories in Rochester
CPT Code Information
84443
84439-(if appropriate)
84480-(if appropriate)