Test Code PBU Lead, 24 Hour, Urine
Performing Laboratory

Specimen Type
UrineOrdering Guidance
The Centers for Disease Control and Prevention recommends venous blood collection for lead testing; see PBDV / Lead, Venous, with Demographics, Blood
Necessary Information
24-Hour volume (in milliliters) is required.
Specimen Required
Patient Preparation: High concentrations of gadolinium and iodine are known to potentially interfere with most inductively coupled plasma mass spectrometry-based metal tests. If either gadolinium or iodine containing contrast media has been administered, a specimen should not be collected for 96 hours.
Supplies: Urine Tubes, 10 mL (T068)
Collection Container/Tube: Clean, plastic urine container with no metal cap or glued insert
Submission Container/Tube: Plastic, 10-mL urine tube or a clean, plastic aliquot container with no metal cap or glued insert
Specimen Volume: 3 mL
Collection Instructions:
1. Collect urine for 24 hours.
2. Refrigerate specimen within 4 hours of completion of 24-hour collection.
3. See Metals Analysis Specimen Collection and Transport for complete instructions.
Additional Information: See Urine Preservatives-Collection and Transportation for 24-Hour Urine Specimens for multiple collections.
Specimen Minimum Volume
1.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Urine | Refrigerated (preferred) | 28 days |
Ambient | 28 days | |
Frozen | 28 days |
Reference Values
0-17 years: Not established
≥18 years: <2 mcg/24 h
Day(s) Performed
Monday through Friday
CPT Code Information
83655