Test Code MYCO Mycoplasma pneumoniae Antibodies, IgG and IgM, Serum
Ordering Guidance
Detection of IgM or IgG class antibodies to Mycoplasma pneumoniae provides exposure information. The preferred method of diagnosis of acute M pneumoniae infection is by molecular detection; order MPRP / Mycoplasma pneumoniae, Molecular Detection, PCR, Varies.
Specimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
MMYCO | M. pneumoniae Ab, IgM, S by IFA | No | No |
Specimen Type
SerumSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 14 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Heat inactivated specimen | Reject |
Reference Values
IgG: Negative
IgM: Negative
IgM by indirect immunofluorescence: Negative
Day(s) Performed
Monday through Friday
Report Available
Same day/1 to 3 daysSpecimen Retention Time
14 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
86738 x 2-Mycoplasma pneumoniae by EIA
86738-Mycoplasma pneumoniae by indirect IFA (if appropriate)