Sign in →

Test Code MYCO Mycoplasma pneumoniae Antibodies, IgG and IgM, Serum


Ordering Guidance


Detection of IgM or IgG class antibodies to Mycoplasma pneumoniae provides exposure information. The preferred method of diagnosis of acute M pneumoniae infection is by molecular detection; order MPRP / Mycoplasma pneumoniae, Molecular Detection, PCR, Varies.



Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Reflex Tests

Test ID Reporting Name Available Separately Always Performed
MMYCO M. pneumoniae Ab, IgM, S by IFA No No

Specimen Type

Serum

Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 14 days
  Frozen  14 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Heat inactivated specimen Reject

Reference Values

IgG: Negative

IgM: Negative

IgM by indirect immunofluorescence: Negative

Day(s) Performed

Monday through Friday

Report Available

Same day/1 to 3 days

Specimen Retention Time

14 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

86738 x 2-Mycoplasma pneumoniae by EIA

86738-Mycoplasma pneumoniae by indirect IFA (if appropriate)