Test Code MRSA SA MRSA/SA, NAAT
Additional Codes
LAB24325
Collection Method
Nares
Container
Double tipped red culturette swab
Acceptable Specimens
- Double or single swab transport systems equivalent to those listed above with Liquid Stuart or Liquid Aimes medium.
- Single swab transport systems meeting acceptable parameters may be used however a repeat collection will be required if repeat testing is indicated.
Minimum Volume
1 swab
Specimen Stability
Ambient | 24 Hours |
Refrigerated (4°C to 8°C) | 5 Days |
Frozen(-70°C to 0°C) | N/A |
Reference or Target Ranges
Negative
Reportable Units
Positive or Negative
Critical Value
Not defined for this assay
Reasons for Rejection
Hemolysis Threshold | N/A |
Icterus Threshold | N/A |
Lipemia Threshold | N/A |
Other | QNS, contaminated, improperly labled, improper specimen type |
Performance Information
Days and Time Performed | 24/7 |
Expected Turn Around Time |
Stat: 1 hour Routine: 4 hours |
Stat Availability | Yes |
Performing Bench | CPH Microbiology |
Methodology/Method Description | Cepheid GeneXpert |
CPT Codes
87641; 87640
Last review/edit date
2025
Preferred Specimen
- Cepheid Sample Collection Device (900-0370) – double breakaway swab in liquid Aimes.
- Copan Transystem™ 139C - Double Regular Rayon Swab and Liquid Stuart Medium
- Copan Transystem™ 138C Double Regular Rayon Swab and Liquid Amies