Test Code MNB Manganese, Blood
Performing Laboratory

Specimen Type
Whole bloodSpecimen Required
Patient Preparation: High concentrations of gadolinium and iodine are known to potentially interfere with most inductively coupled plasma mass spectrometry-based metal tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.
Supplies:
-Metal Free EDTA 3 mL Tube (T989)
-Metal Free B-D Tube (EDTA), 6 mL (T183)
Container/Tube:
Preferred: Royal blue-top BD vacutainer with EDTA blood collection tube (3 mL) (BD catalog no. 367777) (T989)
Acceptable: Royal blue-top BD Vacutainer Plus with EDTA blood collection tube (6 mL) (BD catalog no. 368381) (T183)
Specimen Volume: 0.3 mL
Collection Instructions:
1. See Metals Analysis Specimen Collection and Transport for complete instructions.
2. Send whole blood specimen in original tube. Do not aliquot.
Specimen Minimum Volume
0.2 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Whole blood | Refrigerated (preferred) | 28 days | |
Ambient | 28 days | ||
Frozen | 28 days |
Reference Values
4.7-18.3 ng/mL
Day(s) Performed
Tuesday
CPT Code Information
83785
Report Available
2 to 8 daysSpecimen Retention Time
14 daysReject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |