Test Code MFCDF Myeloma, High Risk with Reflex Probes, Diagnostic FISH Evaluation, Fixed Cell Pellet
Ordering Guidance
For the most complete genetic evaluation on fresh bone marrow specimens, order MPCDS / mSMART, Plasma Cell Proliferative Disorder, FISH, Bone Marrow.
For evaluation of high-risk abnormalities plus CCND1/IGH fusion on fresh bone marrow specimens, order PCPDS / Plasma Cell Proliferative Disorder, High Risk with Reflex Probes, Diagnostic FISH Evaluation, Bone Marrow.
For testing paraffin-embedded tissue samples from patients with a plasma cell disorder, order PLASF / Plasma Cell Proliferative Disorder, FISH, Tissue.
Testing will be changed to the appropriate test if this test is ordered on paraffin or a fresh bone marrow specimen.
Shipping Instructions
Advise Express Mail or equivalent if not on courier service.
Necessary Information
A reason for testing and a flow cytometry and/or a bone marrow pathology report should be sent with each specimen. The laboratory will not reject testing if this information is not provided, but appropriate testing and interpretation may be compromised or delayed. If this information is not provided, an appropriate indication for testing may be entered by Mayo Clinic Laboratories.
Specimen Required
Container/Tube: Sterile container
Specimen Volume: 1 Fixed cell pellet
Collection Instructions: Place specimen in a sterile container with a 3:1 methanol:glacial acetic acid (or similar) fixative.
Specimen Type
Fixed Cell Pellet Bone MarrowSpecimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Fixed Cell Pellet Bone Marrow | Ambient (preferred) | ||
Refrigerated |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Reference Values
An interpretive report will be provided.
Day(s) Performed
Monday through Friday
Report Available
7 to 10 daysSpecimen Retention Time
4 weeksPerforming Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
88271x6, 88275x3, 88291 x1-FISH Probe, Analysis, Interpretation; 3 probe sets
88271x2, 88275x1-FISH Probe, Analysis; each additional probe set (if appropriate)