Test Code MCM24 Mast Cell Mediators, 24 Hour, Urine
Ordering Guidance
Random urine collections are preferred for patients with episodic symptoms, for example in the context of allergic reactions brought on by specific environmental factors. For random urine collections, order MCMRU / Mast Cell Mediators, Random, Urine.
Specimen Required
Patient Preparation:
1. Patient must not be taking monoamine oxidase inhibitors (MAOI) or aminoguanidine, as these medications increase N-methylhistamine (NMH) levels.
2. Patients taking aspirin or nonsteroidal anti-inflammatory drugs (NSAID) may have decreased concentrations of prostaglandin F2 alpha (23BP). If possible, the patient should discontinue use for 2 weeks or 72 hours, respectively, before specimen collection.
Supplies: Urine Container, 60 mL (T313)
Collection Container/Tube: Plastic urine container
Submission Container/Tube: Plastic, 60-mL urine bottle
Specimen Volume: 20 mL
Collection Instructions:
1. Collect urine for 24 hours.
2. No preservative.
3. Aliquot urine into plastic tube and send to lab.
Additional Information: See Urine Preservatives-Collection and Transportation for 24-Hour Urine Specimens for multiple collections.
Specimen Type
UrineSpecimen Minimum Volume
10 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Frozen | 28 days |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Reference Values
N-METHYLHISTAMINE:
0-5 years: 120-510 mcg/g creatinine
6-16 years: 70-330 mcg/g creatinine
>16 years: 30-200 mcg/g creatinine
2,3-DINOR 11B-PROSTAGLANDIN F2a:
<1802 pg/mg creatinine
LEUKOTRIENE E4:
≤104 pg/mg creatinine
CREATININE:
Males: 930-2955 mg/24 h
Females: 603-1783 mg/24 h
Reference values have not been established for patients who are younger than 18 years.
Day(s) Performed
Monday, Tuesday, Thursday
Report Available
3 to 7 daysSpecimen Retention Time
See individual Test IDsPerforming Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
82542
84150