Test Code LEGI Legionella Culture, Varies
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
VariesAdditional Testing Requirements
Because examination by rapid polymerase-chain reaction (PCR) increases sensitivity and provides faster results, it is strongly recommended to also order LEGRP / Legionella species, Molecular Detection, PCR, Varies.
Necessary Information
Specimen source is required.
Specimen Required
Specimen Type: Lower respiratory
Sources: Bronchoalveolar lavage, bronchial aspirate/brushing/lavage/washing, tracheal/endotracheal secretions/aspirate, sputum
Container/Tube: Sterile container
Specimen Volume: Entire collection
Specimen type: Fresh tissue or biopsy
Sources: Lung, pleura, heart valve, pericardium
Container/Tube: Sterile container
Specimen Volume: 5 mm(3)
Collection Instructions: Aseptically collect a 1 to 2 cm(3) piece of tissue whenever possible
Specimen type: Fluid
Sources: Pericardial, pleural, chest, chest tube drainage, thoracentesis, empyema
Container/Tube: Sterile container
Specimen Volume: 2 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Varies | Refrigerated | 48 hours |
Reference Values
No growth of Legionella species after 7 days of incubation
Day(s) Performed
Monday through Sunday
CPT Code Information
87081-Legionella culture
87077-Ident by MALDI-TOF mass spec (if appropriate)
87153-Aerobe ident by sequencing (if appropriate)
87176-Tissue processing (if appropriate)
Report Available
7 to 10 daysSpecimen Retention Time
2 daysReject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
RMALD | Ident by MALDI-TOF mass spec | No, (Bill Only) | No |
ISAE | Aerobe Ident by Sequencing | No, (Bill Only) | No |
TISSR | Tissue Processing | No, (Bill Only) | No |
Specimen Minimum Volume
See Specimen Required