Test Code LCMSP Microsporidia species, Molecular Detection, PCR, Varies

Specimen Type

Varies


Ordering Guidance


For specimens other than feces or urine, MTBS / Microsporidia Stain, Varies should be ordered since it will detect other microsporidia not targeted by this assay.



Necessary Information


Specimen source is required.



Specimen Required


Submit only 1 of the following specimens:

 

Preferred:

Specimen Type: Unpreserved feces

Supplies:

-Stool container, Small (Random), 4 oz (T288)

-Stool Collection Kit, Random (T635)

Container/Tube: Fecal container

Specimen Volume: 5 g

 

Specimen Type: Preserved feces

Supplies:

-ECOFIX Stool Transport Vial (Kit) (T219)

-Stool Collection Kit, Random (T635)

Container/Tube: ECOFIX preservative

Specimen Volume: 5 g

 

Specimen Type: Urine

Container/Tube: Sterile container

Specimen Volume: 5 mL

Collection Instructions: Mid-stream, clean-catch, suprapubic aspirates and catheterization collections are acceptable. Submit in a clean, sterile container free from preservatives. The first portion of the voided urine (first void) is also acceptable.


Specimen Minimum Volume

Feces: 1 g
Urine: 0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Refrigerated (preferred) 7 days
  Ambient  7 days
  Frozen  7 days

Reject Due To

Urine containing preservatives
Prostate secretions and samples
Feces in preservatives other than ECOFIX
Reject

Reference Values

Negative

Day(s) Performed

Tuesday through Friday

Report Available

2 to 4 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

87798