Sign in →

Test Code HTLVL Human T-Cell Lymphotropic Virus Types I and II (HTLV-I/-II) Antibody Confirmation, Serum

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum SST


Ordering Guidance


This confirmatory assay should be ordered only on serum specimens that are consistently reactive by an antihuman T-cell lymphotropic virus 1 and 2 (anti-HTLV-I/-II) screening immunoassay. For an evaluation that includes screening and confirmation, order HTLVI / Human T-Cell Lymphotropic Virus Types I and II Antibody Screen with Confirmation, Serum.

 

For testing spinal fluid specimens, order HTLLC / Human T-Cell Lymphotropic Virus Types 1 and 2 (HTLV-1/-2) Antibody Confirmation, Spinal Fluid.



Necessary Information


Date of collection is required.



Specimen Required


Collection Container/Tube: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions:

1. Centrifuge blood collection tube per collection tube manufacturer's instructions (eg, centrifuge and aliquot within 2 hours of collection for BD Vacutainer tubes).

2. Aliquot serum into plastic vial.


Specimen Minimum Volume

0.2 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum SST Frozen (preferred)
  Refrigerated  7 days

Reference Values

Negative

Day(s) Performed

Tuesday

CPT Code Information

86689

Report Available

2 to 15 days

Specimen Retention Time

14 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK