Test Code HGBA1C Hemoglobin A1c, Blood
Additional Codes
LAB90
Collection Method
Venous collection
Minimum Volume
0.5ml
Container
Purple (EDTA)
Acceptable Specimens
EDTA Whole Blood
Reference or Target Ranges
Age | Male | Female |
< 18 years | Reference Range Not Established | Reference Range Not Established |
≥18 years |
4 - 6% comment 1 |
4 - 6% comment 1 |
Comment 1:
The American Diabetes Association (ADA) considers a hemoglobin of ≥ 6.5% as being consistent with a diagnosis of diabetes. Therapeutic goals for diabetic glycemic control in adults is a hemoglobin A1c of 8.0%, the ADA suggests reevaluation of the treatment regimen. The testing method used is NGSP certified and is standardized to the Diabetes Control and Complication Trial (DCCT) reference method.
Reportable Units
% (percentage)
Critical Value
Not defined for this assay
Reasons for Rejection
Hemolysis Threshold | N/A |
Icterus Threshold | 60 mg/dL |
Lipemia Threshold | 600 mg/dL |
Other | QNS, contaminated, improperly Labeled, improper specimen type |
Specimen Stability
Ambient | 3 days |
Refrigerated (4°C to 8°C) | 7 days |
Frozen(-40°C to 0°C) | N/A |
Performance Information
Days and Time Performed | 24/7 |
Expected Turn Around Time |
Stat: 1 hour Routine: 4 hours |
Stat Availability | Yes |
Performing Bench | CPH Chemistry |
Methodology/Method Description | Roche Cobas |
CPT Codes
83036
Last review/edit date
2025