Sign in →

Test Code FUROC UroVysion for Detection of Bladder Cancer, Urine

Specimen Type

Varies


Necessary Information


1. Specimen source is required on request form (ie, voided, catheterized, bladder washing).

2. Provide fixative, source, reason for referral (evaluate for urothelial carcinoma or hematuria) and status of diagnosis (known previous diagnosis or suspected/unknown).



Specimen Required


Specimen Type: Urine

Sources: Voided urine, catheterized urine, bladder washings, stoma collections, ureteral brushings or washings, renal pelvic brushings or washings

Supplies: FISH for Urothelial Carcinoma Urine Collection Kit (T509)

Container/Tube:

Preferred: FISH for Urothelial Carcinoma in Urocyte Urine Collection Kit

Acceptable: 70% ethanol, PreservCyt, CytoLyt, ThinPrep UroCyte (UroCyte PreservCyt Solution)

Specimen Volume: 30 mL

Collection Instructions:

1. Follow instructions included with Urocyte Urine Collection Kit.

2. If kit is not used, submit a random urine specimen with an equal volume of 70% ethanol, PreservCyt, or CytoLyt.


Specimen Minimum Volume

See Specimen Required

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Refrigerated (preferred)
  Ambient 

Reject Due To

Unfixed specimens 48 hours after collection Reject

Reference Values

An interpretive report will be provided.

Day(s) Performed

Monday through Friday

Report Available

7 to 10 days

Specimen Retention Time

Processed samples: Normal: 1 year; Abnormal: Indefinitely

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

88120