Sign in →

Test Code FENT Fentanyl Screen, Urine

Additional Codes

LAB25488

Collection Method

Sterile Urine Collection

Minimum Volume

5ml

Container

Sterile Cup

Acceptable Specimens

Urine

Reference or Target Ranges

Negative

Reportable Units

Preliminary Positive or Negative

Critical Value

Not defined for this assay

Reasons for Rejection

Hemolysis Threshold N/A
Icterus Threshold N/A
Lipemia Threshold N/A
Other QNS, contaminated, improperly labeled, improper specimen type

Specimen Stability

Ambient 4 weeks
Refrigerated (4°C to 8°C) 4 weeks
Frozen(-40°C to 0°C) 6 months

Performance Information

Days and Time Performed 24/7
Expected Turn Around Time Stat: 1 hour
Routine: 4 hours
Stat Availability Yes
Performing Bench CPH Chemistry
Methodology/Method Description Roche Cobas

CPT Codes

80307

Last review/edit date

Feb 2024