Test Code ALTN Alternaria tenuis, IgE, Serum
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
SerumOrdering Guidance
For a listing of allergens available for testing, see Allergens - Immunoglobulin E (IgE) Antibodies.
Specimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL for every 5 allergens requested
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
For 1 allergen: 0.3 mL
For more than 1 allergen: (0.05 mL x number of allergens) + 0.25 mL deadspace
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 90 days |
Reference Values
Class |
IgE kU/L |
Interpretation |
0 |
<0.10 |
Negative |
0/1 |
0.10-0.34 |
Borderline/equivocal |
1 |
0.35-0.69 |
Equivocal |
2 |
0.70-3.49 |
Positive |
3 |
3.50-17.4 |
Positive |
4 |
17.5-49.9 |
Strongly positive |
5 |
50.0-99.9 |
Strongly positive |
6 |
≥100 |
Strongly positive |
Reference values apply to all ages.
Day(s) Performed
Monday through Friday
CPT Code Information
86003
Report Available
Same day/1 to 3 daysSpecimen Retention Time
14 daysReject Due To
Gross hemolysis | OK |
Gross lipemia | OK |