Test Code ACE Angiotensin Converting Enzyme, Serum

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Necessary Information


The use of angiotensin converting enzyme (ACE)-inhibiting antihypertensive drugs will cause decreased ACE values. Patients taking ACE inhibitors, such as captopril and enalapril, will have extremely low or unmeasurable ACE activity. Indicate on the request form if the patient is on ACE inhibitors.



Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial


Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 7 days
  Frozen  180 days
  Ambient  24 hours

Reference Values

≥18 years: 16-85 U/L

0-17 years: Angiotensin converting enzyme activity may be 20-50% higher in healthy children compared to healthy adults.

 

For SI unit Reference Values, see https://www.mayocliniclabs.com/order-tests/si-unit-conversion.html

Day(s) Performed

Monday through Friday

CPT Code Information

82164

Report Available

1 to 3 days

Specimen Retention Time

7 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject