Test Code AC1Q Anti-C1q Antibodies, IgG, Serum
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Type
SerumSpecimen Minimum Volume
0.4 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 21 days | |
Frozen | 21 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | Reject |
Reference Values
<20 U/mL (Negative)
20-39 U/mL (Weak Positive)
40-80 U/mL (Moderate Positive)
>80 U/mL (Strong Positive)
Day(s) Performed
Wednesday
Report Available
2 to 8 daysSpecimen Retention Time
2 weeksPerforming Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
83520